← Asset Management

Sample reports

What our reports actually look like.

Two real inspections, abridged. Every report documents each roof element with location, observation, photographic evidence and a prioritised recommendation — written by licensed roofing contractors, not just inspectors.

Sample report

Heritage Slate Roof

Heritage estate — Sydney, NSW

Ref · CAM-SAMPLE-SLATE Compiled by · Combined Asset Management Drone & on-foot

01 Background

The maintenance team required an inspection of a key heritage building on the property. Access was by drone and on foot, with every roof plane photographed and assessed.

02 Roof summary

Roof designHipped style roof
Roof materialWelsh Penrhyn slate
Roof profileShingle style
Roof pitch45 degrees
Roof height2–3 storeys
Rainwater systemCopper rainwater goods
Gutter profileQuad — 136mm
Downpipes100–150mm round
Overall current condition2 / 10
PoorExcellent

Critical — end of serviceable life

03 Findings — selected

  • 01

    Roof slates

    Full replacement advised

    Location: Entire roof

    Observation: This roof consists of Welsh Penrhyn slates, generally in deteriorated condition. Many slates demonstrate cracks, posing a significant water ingress threat. Further slipped slates are evident across the roof. Variations in age and profile demonstrate previous maintenance.

    Recommendation: Given the extent of mixed repairs and the deteriorated condition of the slates, full replacement is advised. Budgeting for a re-roof program is recommended.

    Slate field showing mixed profiles and discolouration from previous repairs
    Slate field showing mixed profiles and discolouration from previous repairs
    Variations in age and profile across the roof plane
    Variations in age and profile across the roof plane
  • 03

    Valleys

    Full replacement advised

    Location: Wherever two roof planes meet

    Observation: Lead valleys are heavily oxidised and showing advanced fatigue throughout. Slates abutting the valleys are slipping and, in some cases, loose and blocking the valleys. Previous temporary repairs are evident.

    Recommendation: Given the extent of mixed repairs and the deteriorated condition of the valleys, full replacement is advised as part of a re-roof program.

    Lead valley between roof planes with abutting slates
    Lead valley between roof planes with abutting slates
    Valley alongside the chimney stack
    Valley alongside the chimney stack
  • 06

    Lead box gutter

    Full replacement advised

    Location: Internal lead box gutter

    Observation: The lead lining along the panels is heavily oxidised and has reached the end of its serviceable life. Visible fatigue cracking and surface delamination is evident throughout. Several slates at the gutter edge are cracked or displaced, posing an opportunity for water ingress.

    Recommendation: Full replacement of the box gutter is advised. Budgeting for a re-roof program is recommended.

    Internal lead box gutter between roof planes
    Internal lead box gutter between roof planes
    Box gutter run — oxidised lead lining
    Box gutter run — oxidised lead lining
  • 10

    Batten roll roof

    Critical

    Location: To the face of the building

    Observation: This roof is showing a significant level of surface corrosion — the entire roof is covered in advanced rust. Flashings and gutter components appear equally corroded, indicating the end of their serviceable life.

    Recommendation: Given the deteriorated condition of the batten roll roof, full replacement is advised.

    Batten roll roof — advanced surface corrosion
    Batten roll roof — advanced surface corrosion
    Corroded batten roll panels adjacent to slate
    Corroded batten roll panels adjacent to slate

Selected findings shown — the full report documents every roof element in this format.

04 Conclusion

The entire roof is in a critical condition and has reached the end of its serviceable life across multiple systems simultaneously.

Recommendations summary: Budget for a full re-roof program covering slates, ridges, valleys, flashings, box gutter, eaves gutters and downpipes. A detailed scope of work and budget aligned with this report can be provided on request.

Combined Asset Management · a division of Combined Roofing Australia 02 9666 1592 · asset@roofingsolutions.com.au
Sample report

Commercial Metal Roof

Example report — Sydney, NSW

Ref · CAM-SAMPLE-METAL Compiled by · Combined Asset Management Drone & on-foot

01 Background

Commissioned to investigate an active leak. The roof was assessed element by element, with the leak traced to the roof plumbing rather than the roof sheeting itself — a distinction that changes the scope and the cost considerably.

02 Roof summary

Roof designPitched, layered metal roof
Roof materialColorbond
Roof profileSpandek
Roof pitch30 degrees
Roof heightSingle storey
Rainwater systemEaves gutters
Gutter profileRectangle
DownpipesRound
Overall current condition6 / 10
PoorExcellent

Satisfactory — targeted rectification required

03 Findings — selected

  • 03

    Flashings

    Budget for rectification

    Location: Entire roof

    Observation: Flashings on this roof are of concern. Evidence of numerous band-aid repairs has been made to flashings — this indicates previous leaks in relation to the flashings. Whilst we have not linked the flashings to the current leaks, it is likely they could become defective soon. Note that due to dissimilar metals, the lead over-flashing is beginning to affect the steel.

    Recommendation: Begin budgeting for rectification.

    Capping and flashing at the hip junction
    Capping and flashing at the hip junction
    Flashing detail over the hip
    Flashing detail over the hip
  • 04

    Eaves gutters

    Clean & install leaf guard

    Location: Perimeter of roof

    Observation: The leaks related to this roof are in relation to the gutter systems and associated components. Due to large amounts of surrounding trees, debris builds up in the gutter systems, which is greatly impacting the roof’s ability to efficiently direct water.

    Recommendation: Clean gutters and install leaf guard to combat debris build-up.

    Eaves gutter along the roof perimeter
    Eaves gutter along the roof perimeter
    Gutter line where roof planes meet
    Gutter line where roof planes meet
  • 05

    Downpipes

    Budget for rectification

    Location: Perimeters of roof

    Observation: The current issues with this leak relate to roof plumbing. The downpipes are of significant concern — they are clogged with debris, which then builds up in the valley. This acts as a dam, preventing water from being correctly directed and placing pressure on other roof items.

    Recommendation: Budget for rectification. Clean out gutters and downpipes, and install leaf guard.

    Gutter outlet and downpipe connection
    Gutter outlet and downpipe connection
    Downpipe discharging at ground level
    Downpipe discharging at ground level
  • 06

    Valleys

    Clean & install leaf guard

    Location: Entire roof

    Observation: In correlation with the rest of the roof plumbing systems, the valleys occupying this roof are also of concern. Debris is building up in the valleys and acting as a dam, not allowing water to be correctly directed.

    Recommendation: Clean out valleys and install leaf guard to the valleys alongside the gutters, so debris cannot enter the water course.

    Valley packed with leaf debris, damming water flow
    Valley packed with leaf debris, damming water flow
    Debris accumulation preventing correct drainage
    Debris accumulation preventing correct drainage

Selected findings shown — the full report documents every roof element in this format.

04 Conclusion

The inspection identified several key areas requiring attention to ensure the long-term integrity of the roofing system. While the overall condition of the roof is satisfactory, specific issues need to be addressed to prevent future damage. The roof sheets are in good condition and unlikely to be the cause of any leaks; the roof screws, however, are in poor condition with significant rusting and should be replaced. The gutter system, downpipes and valleys are experiencing significant debris build-up from surrounding trees, impeding water flow and causing the blockages behind the reported leak.

Recommendations summary: Replace corroded roof screws, begin budgeting for flashing rectification, and clean out gutters, downpipes and valleys. Installing leaf guard is recommended to prevent recurrence. Continue annual inspection of sheets and flashings.

Combined Asset Management · a division of Combined Roofing Australia 02 9666 1592 · asset@roofingsolutions.com.au

Want a report like this on your building?

Drone and on-foot inspection, documented findings and trade-accurate costings — typically within 7 business days.